Loading...
Validation of Low Resistance Filters for Gas/Vapour Sampling.
Alarfaj, Ayman M.A.
Alarfaj, Ayman M.A.
Publication Date
2010-03-10T16:51:42Z
End of Embargo
Supervisor
Rights

The University of Bradford theses are licenced under a Creative Commons Licence.
Peer-Reviewed
Open Access status
Accepted for publication
Institution
University of Bradford
Department
Division of Archaeological, Geographical and Environmental Sciences School of Life Sciences
Awarded
2009
Embargo end date
Collections
Additional title
Abstract
Traditional occupational hygiene assessment of occupational exposures to organic gases and vapours rely on low flow (<200 ml/min) NIOSH sorbent tubes. This work investigates 3M charcoal filter media (JK50 and JK40, 3M, Inc.) for collection and analysis of organic vapours across 0.1 ¿ 5 l/min. To enable this work, a custom exposure facility was constructed and validated within which organic analyte gas/vapour concentrations could be introduced at known concentrations while controlling environmental variables such as temperature and humidity and other variables. This facility enabled experiments designed to investigate collection and desorption efficiencies across a range of sample flow rates, temperature and humidity conditions for both NIOSH sorbent tubes (e.g. SKC tube) and 3M charcoal filter media. As a result of the investigations described in this thesis, the following conclusions are drawn.
Performance of the 3M charcoal filter media for collection and desorption efficiencies for loading, storage time, humidity and breakthrough at low flow rates (<0.5 l/min) were found comparable to the SKC sorbent tube. It is concluded that 3M charcoal media (JK50 and JK40) are suitable for sampling and analyses of hydrocarbons at flow rates <0.5 l/min.
The collection efficiencies of the 3M charcoal filter media were investigated at high flow rates (>0.5l/min) for the same parameters, i.e., loading, temperature and humidity. It is concluded that 3M charcoal filter media can be used with confidence in sampling and analysis of airborne hydrocarbons up to 5 l/min.
The Wheeler-Jonas model was found to satisfactorily predict the adsorption kinetics of the 3M charcoal filter media at different loading values of hydrocarbons. It was therefore concluded that the model can be applied to determine the suitable amount of 3M charcoal filter media prior to sampling for a given loading.
Version
Citation
Link to publisher’s version
Link to published version
Link to Version of Record
Type
Thesis
Qualification name
PhD