This is an author-created, un-copyedited version of an article accepted for published in Materials Research Express. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/2053-1591/aaf5eb.
Peer-Reviewed
Yes
Open Access status
openAccess
Accepted for publication
2018-12-04
Institution
Department
Awarded
Embargo end date
Additional title
Abstract
Polyetheretherketone (or PEEK) is a thermoplastic polymer known for its high plasticity and toughness and has been widely employed as a material for a variety of load-bearing medical devices ranging from trauma implants to interspinal spacers and femoral stems. While being inherently chemically inert and therefore biocompatible and having very short lived post-radiation free radicals, PEEK presents different mechanical properties depending on its degree of crystallinity. It can be processed via extrusion, injection or compression moulding. However, these techniques do not allow high precision control over the fine morphological structure that strongly influences mechanical properties. Microinjection moulding, in contrast, makes it possible to produce fine details of medical implants with high precision and accuracy. Another advantage of this method is the controlled production of the material with heterogeneous structure due to variations in crystallinity. Having stiffness in the middle of the sample different from that at the edges enables a structure that mimics the bone/cartilage parts of an implant. This paper reports on the manufacturing of PEEK components by microinjection moulding, and their characterisation by physico-chemical (XRD, SAXS, TEM, FTIR, POM) and mechanical (tensile testing) means, in order to assess the suitability of use for biomedical application, such as spinal implants. We discuss the influence of such parameters as mould temperatures, injection speeds and hold pressures on the crystallinity and mechanical properties of the material.
Version
Accepted manuscript
Citation
Tuinea-Bobe C-L, Xia H, Ryabenkova Y et al (2019) Microinjection moulded polyetheretherketone biomaterials as spinal implants: physico-chemical and mechanical characterisation. Materials Research Express. 6(3): 035311.
Link to publisher’s version
Link to published version
Link to Version of Record
Type
Article