Effect of Concrete Strength and Stud Collar Size to Shear Capacity of Demountable Shear Connectors
Publication date
2015Peer-Reviewed
YesOpen Access status
closedAccess
Metadata
Show full item recordAbstract
In this paper, a group of demountable shear connectors have been developed and tested to assess their potential and suitability in terms of replacing welded shear studs. The experiments showed that these demountable shear connectors can be easily demounted after testing and have similar capacity and behavior to those of welded shear connectors. After the numerical simulation method had been validated against experimental observation, a parametric study was carried out to understand the effect of concrete grades and stud collar sizes on the shear resistance of demountable shear connections. Simple design calculation methods for welded shear connections or anchoring connections provided in European and American standards were checked to the suitability for assessment of this headed demountable shear connector. (C) 2015 American Society of Civil Engineers.Version
No full-text in the repositoryCitation
Dai X, Lam D and Saveri E (2015) Effect of Concrete Strength and Stud Collar Size to Shear Capacity of Demountable Shear Connectors. Journal of Structural Engineering. 141(11): article number 04015025.Link to Version of Record
https://doi.org/10.1061/(Asce)St.1943-541x.0001267Type
Articleae974a485f413a2113503eed53cd6c53
https://doi.org/10.1061/(Asce)St.1943-541x.0001267