dc.description.abstractThe performance of Ground Source Heat Pump (GSHP) systems for domestic use is an increasing area of study in the UK. This paper examines the thermal performance of three bespoke shallow horizontal GSHP systems installed in newly built residential houses in the North of England against a control house which was fitted with a standard gas boiler. A total of 350 metres of High Density Polyethylene pipe with an external diameter of 40 mm was used for each house as a heat pump loop. The study investigated (i) the performance of a single loop horizontal Ground Heat Exchanger (GHE) against a double loop GHE and (ii) rainfall effects on heat extraction by comparing a system with an infiltration trench connected to roof drainage against a system without an infiltration trench above the ground loops. Parameters monitored for a full year from October 2013 to September 2014. Using the double GHE has shown an enhanced performance of up to 20% compared with single GHE. The infiltration trench is found to improve performance of the heat pumps; the double loop GHE system with an infiltration trench had a COP 5% higher than that of the double loop GHE system without a trench.en_US
dc.language.isoenen_US
dc.rights(c) 2016 Thomas Telford. Full-text reproduced in accordance with the publisher's self-archiving policy.en_US
dc.subjectGround Source Heat Pump; GSHP; Coefficient of performance; COP; Ground Heat Exchanger; GHE; GSHP Field Data; Rainfall infiltrationen_US
dc.titleAnalysis of ground-source heat pumps in north-of-England homesen_US
dc.status.refereedYesen_US
dc.date.Accepted2016-04-22
dc.date.application2016-06-09
dc.typeArticleen_US
dc.type.versionAccepted Manuscripten_US
dc.identifier.doihttps://doi.org/10.1680/jener.15.00022
refterms.dateFOA2018-07-25T12:38:39Z


Item file(s)

Thumbnail
Name:
mohamed_ice_energy.pdf
Size:
1.752Mb
Format:
PDF
Description:
Keep suppressed
Thumbnail
Name:
Mohamed_ice_energy_2.pdf
Size:
1.820Mb
Format:
PDF
Description:
Keep suppressed - changes to ...
Thumbnail
Name:
Mohamed_ice_energy_2.pdf
Size:
1.824Mb
Format:
PDF
Description:
Main article

This item appears in the following Collection(s)

Show simple item record