Composite behaviour of headed stud shear connectors in pairs with profiled metal deck flooring
Abstract
This paper presents the experimental and numerical investigation into the behaviour of headed shear studs in composite beams with profiled metal deck flooring. A new single-sided horizontal push test arrangement is proposed to evaluate the shear capacity of the headed shear connectors in pairs with metal deck profiled sheeting. The characteristic resistance obtained from the horizontal push test is compared with Eurocode 4. A three-dimensional finite element model was developed using general purpose finite element program ABAQUS/Explicit. The shear connector capacity, load-slip behaviour and failure modes are validated against experimental results and close correlations were obtained.Version
No full-text in the repositoryCitation
Lam D, Qureshi J and Ye J (2010) Composite behaviour of headed stud shear connectors in pairs with profiled metal deck flooring. In: Proceedings of the 4th International Conference on Steel & Composite Structures. 4th International Conference on Steel & Composite Structures, 2009, Sydney, Australia.Link to Version of Record
https://doi.org/10.3850/978-981-08-6218-3_key-5Type
Conference paperae974a485f413a2113503eed53cd6c53
https://doi.org/10.3850/978-981-08-6218-3_key-5