Show simple item record

dc.contributor.authorMcBride, L.
dc.contributor.authorJames, Rob S.
dc.contributor.authorAlsop, S.
dc.contributor.authorOxford, S.W.
dc.date.accessioned2023-01-23T18:05:21Z
dc.date.accessioned2023-02-08T11:02:53Z
dc.date.available2023-01-23T18:05:21Z
dc.date.available2023-02-08T11:02:53Z
dc.date.issued2022-12
dc.identifier.citationMcBride L, James RS, Alsop S and Oxford SW (2022) Intra and Inter-Rater Reliability of a Novel Isometric Test of Neck Strength. Sports. 11(1): 2.
dc.identifier.urihttp://hdl.handle.net/10454/19318
dc.descriptionYes
dc.description.abstractThere is no single, universally accepted method of measuring isometric neck strength to inform exercise prescription and injury risk prediction. This study aimed to establish the inter- and intra-rater reliability of a commercially available fixed frame dynamometer in measuring peak isometric neck strength. A convenience sample of male (n = 16) and female (n = 20) university students performed maximal isometric contractions for flexion (Flex), extension (Ext), left- (LSF) and right-side flexion (RSF) in a quadruped position over three sessions. The intra-rater reliability results were good-to-excellent for both males (ICC = 0.83–0.90) and females (ICC = 0.86–0.94) and acceptable (CV < 15%) across all directions for both males and females. The inter-rater reliability results were excellent (ICC = 0.96–0.97) and acceptable (CV < 11.1%) across all directions. Findings demonstrated a significant effect for sex (p ≤ 0.05): males were stronger in all four directions, and a significant effect for direction (p ≤ 0.05): Ext tested stronger (193 N) than Flex (176 N), LSF (130 N) and RSF (125 N). The findings show that the VALD fixed frame dynamometer can reliably assess isometric neck strength and can provides reference values for healthy males and females.
dc.language.isoenen
dc.rights© 2022 The Authors. This is an Open Access article distributed under the terms and conditions of the Creative Commons CC-BY license (https://creativecommons.org/licenses/by/4.0/)
dc.subjectCervical spine
dc.subjectNeck strength
dc.subjectMuscle testing
dc.subjectTest-retest
dc.subjectProfiling
dc.subjectPeak force
dc.subjectFixed frame dynamometer
dc.titleIntra and Inter-Rater Reliability of a Novel Isometric Test of Neck Strength.
dc.status.refereedYes
dc.typeArticle
dc.type.versionPublished version
dc.identifier.doihttps://doi.org/10.3390/sports11010002
dc.rights.licenseCC-BY
dc.date.updated2023-01-23T18:05:24Z
refterms.dateFOA2023-02-08T11:04:45Z
dc.openaccess.statusopenAccess
dc.date.accepted2022-12-09


Item file(s)

Thumbnail
Name:
Sportsv2LMcB.docx
Size:
1.472Mb
Format:
Microsoft Word 2007
Thumbnail
Name:
sports-11-00002.pdf
Size:
880.4Kb
Format:
PDF
Description:
Main article

This item appears in the following Collection(s)