Numerical study on flexural and bond-slip behaviours of GFRP profiled-concrete composite beams with groove shear connector
View/ Open
Ashour_et_al_Engineering_Structures_2023 (4.126Mb)
Download
Publication date
2023-01Keyword
GFRP profiled-concrete composite beamFlexural performance
Bond-slip behaviour
Traction-separation model
Rights
© 2022 Elsevier Ltd. All rights reserved. Reproduced in accordance with the publisher's self-archiving policy. This manuscript version is made available under the CC-BY-NC-ND 4.0 license.Peer-Reviewed
YesOpen Access status
openAccess
Metadata
Show full item recordAbstract
GFRP profiled-concrete composite beams with groove shear connectors are analyzed using finite the element (FE) analysis. The concrete damaged plasticity (CDP) model was adopted for normal strength concrete (NSC) and reactive powder concrete (RPC). The orthotropic behaviour of GFRP profile was taken into consideration, and the bi-linear traction-separation model was used to investigate the bond-slip behavior between GFRP profile and concrete. Furthermore, parametric studies were conducted to investigate the effects of strength and the cross-sectional dimensions of concrete, strength (orthotropy), and the cross-sectional dimensions (the web height and the thickness of FRP plate). Numerical analysis results correlate well with experimental results. Based on numerical analysis, the composite beam with shear connectors spacing at 100 mm has a deflection-limit load of 21.4 % higher than the specimens with 150 mm spacing. It is possible to improve the bonding behavior of interfaces by using groove shear connectors. The ultimate load and deformation, and pseudo-ductility were significantly improved by using RPC with high strength and toughness (ultimate compressive strain). GFRP profiles with greater orthotropy coefficients provide fully utilized concrete's compressive strength, preventing premature crushing and enhancing composite structure stiffness. Flexural performance of the composite beams can be improved efficiently by choosing the appropriate sectional size during design and construction.Version
Accepted manuscriptCitation
Ge W, Zhang Z, Guan Z et al (2023) Numerical study on flexural and bond-slip behaviours of GFRP profiled-concrete composite beams with groove shear connector. Engineering Structures. 275(Part A): 115226.Link to Version of Record
https://doi.org/10.1016/j.engstruct.2022.115226Type
Articleae974a485f413a2113503eed53cd6c53
https://doi.org/10.1016/j.engstruct.2022.115226