Show full item recordAbstract
To assess how objectively-detected defects of retinal nerve fibre bundle (RNFB) reflectance in en face OCT images relate to circumpapillary retinal nerve fibre layer thickness (cpRNFLT) and visual field defects. Cross-sectional study. 16 participants with early-glaucoma and 29 age-similar healthy controls, among which 22 had usable en face images to establish normative levels of RNFB reflectance. All participants underwent cpRNFLT scans, visual field examination and wide-field OCT. En face reflectivity was assessed objectively using the Summary of Multiple Anatomically-Adjusted Slabs (SMAS) method. En face defects were deemed concordant with cpRNFLT when they had at least one cpRNFLT point with pVersion
Published versionCitation
Cheloni R and Dennis J (2023) Concordance of objectively-detected retinal nerve fiber bundle defects in en face OCT images with conventional structural and functional changes in glaucoma. Ophthalmology Glaucoma. 6(1): 78-92.Link to Version of Record
https://doi.org/10.1016/j.ogla.2022.07.001Type
Articleae974a485f413a2113503eed53cd6c53
https://doi.org/10.1016/j.ogla.2022.07.001