Show simple item record

dc.contributor.authorAdler, P.
dc.contributor.authorScally, Andy J.
dc.contributor.authorBarrett, Brendan T.
dc.date.accessioned2020-02-13T11:44:24Z
dc.date.accessioned2020-03-06T11:40:27Z
dc.date.available2020-02-13T11:44:24Z
dc.date.available2020-03-06T11:40:27Z
dc.date.issued2018-11
dc.identifier.citationAdler P, Scally AJ and Barrett BT (2018) Test-retest reproducibility of accommodative facility measures in primary school children. Clinical and Experimental Optometry. 101(6): 764-770.
dc.identifier.urihttp://hdl.handle.net/10454/17682
dc.descriptionYes
dc.description.abstractTo determine the test-retest reproducibility of accommodative facility (AF) measures in an unselected sample of UK primary school children. Methods: Using 2.00 DS flippers and a viewing distance of 40 cm, AF was measured in 136 children (range 4–12 years, average 8.1 2.1) by five testers on three occasions (average interval between successive tests: eight days, range 1–21 days). On each occasion, AF was measured monocularly and binocularly, for two minutes. Full datasets were obtained in 111 children (81.6 per cent). Results: Intra-individual variation in AF was large (standard deviation [SD] = 3.8 cycles per minute [cpm]) and there was variation due to the identity of the tester (SD = 1.6 cpm). On average, AF was greater: (i) in monocular compared to binocular testing (by 1.4 cpm, p < 0.001); (ii) in the second minute of testing compared to the first (by 1.3 cpm, p < 0.001);(iii) in older compared to younger children (for example, AF for 4/5-year-olds was 3.3 cpm lower than in children ≥10 years old, p = 0.009); and (iv) on subsequent testing occasions (for example, visit-2 AF was 2.0 cpm higher than visit-1 AF, p < 0.001). After the first minute of testing at visit-1, only 36.9 per cent of children exceeded published normative values for AF (≥11 cpm monocularly and≥8 cpm binocularly), but this rose to 83.8 per cent after the third test. Using less stringent pass criteria (≥6 cpm monocularly and≥3 cpm binocularly), the equivalent figures were 82.9 and 96.4 per cent, respectively. Reduced AF did not co-exist with abnormal near point of accommodation or reduced visual acuity. Conclusions: The results reveal considerable intra-individual variability in raw AF measures in children. When the results are considered as pass/fail, children who initially exhibit normal AF continued to do so on repeat testing. Conversely, the vast majority of children with initially reduced AF exhibit normal performance on repeat testing. Using established pass/fail criteria, the prevalence of persistently reduced AF in this sample is 3.6 per cent.
dc.description.sponsorshipUK College of Optometrists
dc.language.isoen
dc.language.isoenen
dc.rights© 2018 Wiley. This is the peer-reviewed version of the following article: Adler P, Scally AJ and Barrett BT (2018) Test-retest reproducibility of accommodative facility measures in primary school children. Clinical and Experimental Optometry. 101(6): 764-770, which has been published in final form at https://doi.org/10.1111/cxo.12691. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.
dc.subjectAccommodation
dc.subjectAccommodative dysfunction
dc.subjectAccommodative facility
dc.subjectChildren's vision
dc.titleTest-retest reproducibility of accommodative facility measures in primary school children
dc.status.refereedYes
dc.date.application2018-05-08
dc.typeArticle
dc.type.versionAccepted manuscript
dc.identifier.doihttps://doi.org/10.1111/cxo.12691
dc.identifier.doihttps://doi.org/10.1111/cxo.12691
dc.rights.licenseUnspecified
dc.rights.licenseUnspecified
dc.date.updated2020-02-13T11:44:25Z
refterms.dateFOA2020-03-16T17:03:23Z
dc.openaccess.statusopenAccess
dc.openaccess.statusopenAccess
dc.date.accepted2018-03-28


Item file(s)

Thumbnail
Name:
Barrett_et_al_CEO.pdf
Size:
589.6Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record