Show simple item record

dc.contributor.authorAlhawat, Musab M.*
dc.contributor.authorAshour, Ashraf F.*
dc.date.accessioned2019-02-26T13:21:35Z
dc.date.available2019-02-26T13:21:35Z
dc.date.issued2019-06
dc.identifier.citationAlhawat MM and Ashour AF (2019) Bond strength between corroded steel reinforcement and recycled aggregate concrete. Structures. 19: 369-385.en_US
dc.identifier.urihttp://hdl.handle.net/10454/16849
dc.descriptionYesen_US
dc.description.abstractThis paper investigates the bond performance of recycled coarse aggregate (RCA) concrete with un-corroded/corroded reinforcing steel bars, with the main parameters being RCA content, corrosion level, bar diameter and embedment length. For this purpose, 60 pull-out specimens containing different percentages of RCA (i.e. 0%, 25%, 50% and 100%) and steel bars of two diameters (12 and 20 mm) and different embedment lengths were tested. In order to establish various levels of corrosion, specimens were exposed to an electrochemical corrosion for 2, 5, 10 and 15 days. The bond strength between RAC concrete and un-corroded/corroded steel are compared to current codes and equations proposed by other researchers. Experimental results showed that larger corrosion rate of steel bars was observed with the increase of the replacement level of RCA due to its high porosity and water absorption. The use of RCA had a slight influence on bond strength for un-corroded specimens compared to that obtained from conventional concrete. Furthermore, the bond strength of RCA concrete was strongly affected by corrosion products; bond strength slightly enhanced for up to about 2% corrosion rate, and then significantly decreased as the corrosion time further increased, similar to that of conventional concrete. However, the rate of bond degradation between RCA concrete and corroded steel bars was much faster than that observed in corroded conventional concrete.en_US
dc.language.isoenen_US
dc.relation.isreferencedbyhttps://doi.org/10.1016/j.istruc.2019.02.001en_US
dc.rights© 2019 Institution of Structural Engineers. Published by Elsevier Ltd. All rights reserved. Reproduced in accordance with the publisher's self-archiving policy. This manuscript version is made available under the CC-BY-NC-ND 4.0 license.en_US
dc.subjectRecycled coarse aggregaten_US
dc.subjectCorrosionen_US
dc.subjectBond strengthen_US
dc.subjectEmbadment lengthen_US
dc.subjectSteel bar sizeen_US
dc.subjectPull-out testen_US
dc.titleBond strength between corroded steel reinforcement and recycled aggregate concreteen_US
dc.status.refereedYesen_US
dc.date.Accepted2019-02-04
dc.date.application2019-02-05
dc.typeArticleen_US
dc.type.versionAccepted manuscripten_US
refterms.dateFOA2019-02-26T13:21:35Z


Item file(s)

Thumbnail
Name:
Ashour_Structures.pdf
Size:
2.120Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record