Publication

Microemulsion High Performance Liquid Chromatography (MELC) for Determination of Terbutaline in Urine Samples

Althanyan, Mohammed S.
Nasser, A.
Assi, H.
Clark, Brian J.
Assi, Khaled H.
Publication Date
2016-02
End of Embargo
Supervisor
Rights
Peer-Reviewed
Yes
Open Access status
closedAccess
Accepted for publication
2015-10-10
Institution
Department
Awarded
Embargo end date
Additional title
Abstract
An isocratic oil-in-water microemulsion High Performance Liquid Chromatography (MELC) was developed and validated for the determination of terbutaline in urine samples. A solid phase extraction (SPE) method which used Oasis HLB cartridges was optimised to isolate terbutaline from a urine matrix followed by HPLC with fluorescence detection. The urinary assay was performed in accordance with FDA and ICH regulations for the validation of bioanalytical samples. The method uses the isocratic oil-in-water micro emulsion to separate the terbutaline from the endogenous urine components. The chromatographic separation was carried out on C18-Spherisorb (250mm×4.6mm) analytical column maintained at 30 °C. The mobile phase was 94.4% aqueous orthophosphate buffer (adjusted to pH 3 with orthophosphoric acid), 0.5% ethyl acetate, 1.5% Brij35, 2.5% 1-butanol and 1.1% Octanesulfonic acid (OSA), all w/w. The terbutaline peak was detected by fluorescence detection, using excitation and emission wavelengths of 267 and 313 nm, respectively. The linearity of response was demonstrated at six different concentrations of terbutaline which were extracted from spiked urine, ranging from 60 to 1000ng/ml. The terbutaline was extracted from urine by a solid phase extraction clean-up procedure on Oasis HLB cartridges, and the relative recovery was >87.64% (n = 5). The limit of detection (LOD) and limit of quantitation (LOQ) in urine were 20.21 and 61.24ng/ml, respectively. The intra-day and inter-day precisions (in term of % coefficient of variation) were <3.56% and <2.87%, respectively. In the method development the influence of the composition of the microemulsion system was also studied and the method was found to be robust with respect to changes of the microemulsion components.
Version
No full-text in the repository
Citation
Althanyan MS, Nasser A, Assi H et al (2016) Microemulsion High Performance Liquid Chromatography (MELC) for Determination of Terbutaline in Urine Samples. International Journal of Pharmaceutical Sciences Reviews and Research. 36(1): 288-282.
Link to publisher’s version
Link to Version of Record
Type
Article
Qualification name
Notes