Loading...
Thumbnail Image
Publication

Experimental study on compressive behavior and failure analysis of composite concrete confined by glass/epoxy ±55° filament wound pipes

Gemi, L.
Koroglu, M.A.
Publication Date
2018-03
End of Embargo
Supervisor
Rights
© 2017 Elsevier. Reproduced in accordance with the publisher's self-archiving policy. This manuscript version is made available under the CC-BY-NC-ND 4.0 license.
Peer-Reviewed
Yes
Open Access status
Accepted for publication
2017-12-20
Institution
Department
Awarded
Embargo end date
Additional title
Abstract
This paper investigates the strength and ductility of concrete confined by Glass/Epoxy ±55° Filament Wound Pipes (GFRP) under axial compression. A total of 24 cylinderical specimens were prepared with expansive and Portland cements, properly compacted and un-compacted for different composite fresh concrete matrix. Test results showed that compressive strength and axial deformation at failure of concrete confined with GFRP tubes increased by an average of 2.85 and 5.57 times these of unconfined concrete, respectively. Macro and micro analyses of GFRP pipes after failure were also investigated. Debonding, whitening, matrix/transfer cracking, delamination and splitting mechanisms were detected at failure, respectively. The experimental results were also employed to assess the reliability of design models available in the literature for confined concrete compressive strength.
Version
Accepted Manuscript
Citation
Gemi L, Koroglu MA and Ashour A (2017) Experimental study on compressive behavior and failure analysis of composite concrete confined by glass/epoxy ±55° filament wound pipes. Composite Structures. 187: 157-168.
Link to publisher’s version
Link to published version
Type
Article
Qualification name
Notes