Loading...
Thumbnail Image
Publication

Normal values and test-retest variability of stimulated-echo diffusion tensor imaging and fat fraction measurements in the muscle

Farrow, Matthew
Grainger, A.J.
Tan, A.L.
Buch, M.H.
Emery, P.
Ridgway, J.P.
Feiweier, T.
Tanner, S.F.
Biglands, J.
Publication Date
2019-09
End of Embargo
Supervisor
Rights
(c) 2019 The Authors.
Peer-Reviewed
Yes
Open Access status
openAccess
Accepted for publication
30/06/2019
Institution
Department
Awarded
Embargo end date
Additional title
Abstract
Objectives: To assess the test-retest variability of both diffusion parameters and fat fraction (FF) estimates in normal muscle, and to assess differences in normal values between muscles in the thigh. Methods: 29 healthy volunteers (mean age 37 years, range 20-60 years, 17/29 males) completed the study. Magnetic resonance images of the mid-thigh were acquired using a stimulated echo acquisition mode-echoplanar imaging (STEAM-EPI) imaging sequence, to assess diffusion, and 2-point Dixon imaging, to assess FF. Imaging was repeated in 19 participants after a 30 min interval in order to assess test-retest variability of the measurements. Results: Intraclass correlation coefficients (ICCs) for test-retest variability were 0.99 [95% confidence interval, (CI): 0.98, 1] for FF, 0.94 (95% CI: 0.84, 0.97) for mean diffusivity and 0.89 (95% CI: 0.74, 0.96) for fractional anisotropy (FA). FF was higher in the hamstrings than the quadriceps by a mean difference of 1.81% (95% CI:1.63, 2.00)%, p < 0.001. Mean diffusivity was significantly lower in the hamstrings than the quadriceps (0.26 (0.13, 0.39) x10-3 mm2s-1, p < 0.001) whereas fractional anisotropy was significantly higher in the hamstrings relative to the quadriceps with a mean difference of 0.063 (0.05, 0.07), p < 0.001. Conclusions: This study has shown excellent test-retest, variability in MR-based FF and diffusion measurements and demonstrated significant differences in these measures between hamstrings and quadriceps in the healthy thigh. Advances in knowledge: Test-retest variability is excellent for STEAM-EPI diffusion and 2-point Dixon-based FF measurements in the healthy muscle. Inter- and intraobserver variability were excellent for region of interest placement for STEAM-EPI diffusion and 2-point Dixon-based FF measurements in the healthy muscle. There are significant differences in FF and diffusion measurements between the hamstrings and quadriceps in the normal muscle.
Version
Published version
Citation
Farrow M, Grainger AJ, Tan AL et al (2019) Normal values and test-retest variability of stimulated-echo diffusion tensor imaging and fat fraction measurements in the muscle. British Journal of Radiology. 92(1101): 20190143.
Link to publisher’s version
Link to published version
Link to Version of Record
Type
Article
Qualification name