Loading...
Development of kerosene–water two-phase up-flow in a vertical pipe downstream of A 90° bend
Hamad, Faik A. ; He, S. ; Khan, M. Khurshid ; Bruun, Hans H.
Hamad, Faik A.
He, S.
Khan, M. Khurshid
Bruun, Hans H.
Publication Date
2013
End of Embargo
Supervisor
Rights
Peer-Reviewed
Open Access status
Accepted for publication
2011-10-31
Institution
Department
Awarded
Embargo end date
Additional title
Abstract
The development of kerosene–water up-flow in a vertical pipe of 77.8 mm inner diameter and 4500 mm, length downstream of a 90◦bend, hasbeen investigated using a Pitot tube and dual optical probe. The CFD ANSYS Fluent 12.0 is used to model the flow and the results are comparedwith experimental data. The CFD provides detailed information on flow structure which is difficult to obtain in experiments. The experimentalmeasurements of the local parameters demonstrate that the single phase and two-phase flows reached the fully developed axisymmetricalconditions at L/D = 54. These results also show the severe asymmetry distributions of the two-phase flow parameters at the entrance region(L/D = 1). The predictions from Fluent are found to be in close agreement with experimental data for L/D ≥ 16 but there is a significant discrepancyat L/D = 1.
Version
No full-text in the repository
Citation
Hamad FA, He S, Khan MK and Bruun HH (2013) Development of kerosene–water two-phase up-flow in a vertical pipe downstream of A 90° bend. The Canadian Journal of Chemical Engineering. 91(2): 354-367.