Concrete Filled Steel Tube Columns - Test compared with Eurocode4
Lam, Dennis ; Goode, C.D.
Lam, Dennis
Goode, C.D.
Publication Date
2008
End of Embargo
Supervisor
Keywords
Rights
Peer-Reviewed
Yes
Open Access status
closedAccess
Accepted for publication
Institution
Department
Awarded
Embargo end date
Additional title
Abstract
This paper summarises the data from 1819 tests on concrete-filled steel tube columns and compares their failure load with the prediction of Eurocode 4. The full data is given on the website http://web.ukonline.co.uk/asccs2 . The comparison with Eurocode 4 is discussed and shows that Eurocode 4 can be used with confidence and generally gives good agreement with test results, the average Test/EC4 ratio for all tests being 1.11. The Eurocode 4 limitations on concrete strength could be safely extended to concrete with a cylinder strength of 75 N/mm2 for circular sections and 60 N/mm2 for rectangular sections.
Version
No full-text in the repository
Citation
Goode, D. and Lam, D. (2008). Concrete Filled Steel Tube Columns ¿ Test compared with Eurocode4. In: Composite Construction VI by R.T. Leon, T. Perea, G.A. Rassati, J. Lange (Eds.). The Sixth International Conference on Composite Construction in Steel and Concrete, July 20-24, 2008, Devil's Thumb Ranch, Colorado, USA.
Link to publisher’s version
Link to published version
Link to Version of Record
Type
Conference paper